Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 43
Filter
1.
Article | IMSEAR | ID: sea-216813

ABSTRACT

Background and Aim of Study: Early childhood caries is a multifactorial disease process affecting children below 71 months of age and continues to be a global health problem. Stainless steel crowns (SSCs) are widely used and are very popular in pediatric dentistry due to its superiority and durability when compared with multisurface amalgam restorations. However, one of the major disadvantages with these crowns is the poor esthetics. Parents often request for a more esthetic alternative to the SSC. Zirconia crowns are one of the tooth-colored full crown restorations currently available for use in primary teeth. These are available as both preformed and custom-made crowns and show excellent esthetics. However, these require extensive tooth preparation with a subgingival finish lines, which would cause gingival trauma and bleeding during the preparation. The present study uses intraoral scanners for making the custom-made zirconia crowns, which will avoid the conventional impressions. Currently, there are no studies available in pediatric dentistry regarding CAD-CAM crowns. Hence, there is a need for the study. Aim: The aim of this study is to clinically evaluate the performance of preformed SSCs and custom-made zirconia crowns in primary molars. To elicit parental and patient satisfaction with respect to preformed SSCs and custom made zirconia crowns and to radiographically compare the interproximal bone height for 1 year. Methods: The patients were selected with purposive sampling. The tooth of interest was prepared according to the crown it would receive. The upper and the lower arch of the tooth receiving custom-made zirconia crown was scanned using an intraoral scanner. The crowns were cemented using Type 1 glass ionomer cement (GIC) (SSC) and resin modified GIC (custom-made zirconia crown). After the crown placement, the patient and the parent's satisfaction was scaled regarding the time taken, comfort, cost of crown, appearance of crown, etc., using a 5-point Likert scale. A baseline radiograph was taken after crown placement. The patient was recalled every 3 months till 1 year for evaluation (loss of retention, loss of proximal contact, gingival inflammation, opposing tooth wear, and marginal integrity). At the end of 1 year, radiographs were taken to check the interproximal bone. Results: After 1 year evaluation of custom-made zirconia crowns and preformed SSCs in primary molars, it was shown that both SSC and zirconia crowns showed good gingival scores but zirconia crown was better than SSC in improving the gingival health. SSCs showed better results with respect to the opposing tooth wear and marginal adaptability. Parents as well as patients preferred a tooth-colored crown as a treatment option. Conclusion: Custom-made zirconia crowns are comparable to the preformed SSCs and they show better gingival scores and excellent color match.

2.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 207-211, 2022.
Article in Chinese | WPRIM | ID: wpr-907046

ABSTRACT

Objective@# To explore the design and manufacture of anatomical healing abutment for mandibular first molar implant in order to provide more choices for clinical healing abutment@*Methods@# The buccal lingual diameter and mesial distal diameter of the tooth neck, as well as the slope data of the four axial surfaces of the natural isolated teeth, were obtained by scanning the isolated mandibular first molar with a shining scanner. After statistical analysis of the data, the anatomical healing abutment of the mandibular first molar was designed and constructed using computer aided design/computer aided manufacturing (CAD/CAM).@*Results@#The mean buccal and lingual diameters of the mesial and distal diameters of the isolated mandibular first molars were (8.54 ± 0.78) mm and (7.87 ± 0.86) mm, and the tooth neck slopes of each axial surface of the isolated mandibular first molars were 17.53 °(buccal), 14.41 °(lingal), 13.40 °(mesial) and 13.43 °(distal), respectively. Three anatomical healing abutments with different peripheral diameters and heights of 5 mm were obtained according to a certain proportion of reduction of the natural teeth of the mandibular first molars@*Conclusion@#The anatomical healing abutment of the mandibular first molar can be quickly obtained by Shining scanning and CAD/CAM technology.

3.
Malaysian Journal of Medicine and Health Sciences ; : 166-172, 2022.
Article in English | WPRIM | ID: wpr-980242

ABSTRACT

@#Custom cast metal posts and cores are time-consuming to make, requiring several clinical and laboratory stages and the use of gold, cobalt-, or nickel-chromium. Aside from the numerous stages involved, a cast metal post and core has a significantly higher modulus of elasticity than the dentinal root structure and, as a result, is more likely to cause root fracture. Furthermore, the metal colour of the post and core, which always appears as a dark shadow beneath a ceramic crown, is an aesthetic concern. Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) of posts and cores is a potential fabrication option for overcoming the issues associated with cast metal posts and cores. Some of the time-consuming clinical and laboratory procedures can be eliminated by using a CAD/CAM machine, and tooth-colored materials can be milled to create custom posts and cores. The marginal and internal adaptation of the CAD/CAM produced posts and cores to the tooth structure, on the other hand, is highly dependent on the scanning accuracy and milling capability of the CAD/CAM machine. Because the majority of studies on dental CAD/ CAM have concentrated on the fabrication of fixed and removable prostheses, data on the marginal accuracy and internal adaptation of CAD/CAM produced posts and cores is limited. As a result, the aim of this review paper is to determine the current state of the market’s CAD/CAM machines in terms of their scanning and milling capability to produce custom posts and cores that match the marginal and fitting accuracy of cast metal posts and cores.

4.
Journal of Peking University(Health Sciences) ; (6): 565-571, 2022.
Article in Chinese | WPRIM | ID: wpr-941003

ABSTRACT

OBJECTIVE@#To investigate the effect of polishing on surface roughness, gloss and optimum polishing time of various computer aided design/computer aided manufacturing (CAD/CAM) restorative materials and to provide a proper polishing procedure for dental clinicians.@*METHODS@#Five CAD/CAM restorative materials including vita mark Ⅱ (VM), vita enamic (VE), lava ultimate (LU), shofu block HC (SB) and brilliant crios (BC) were selected. Six specimens were prepared for each material. The specimen was fixed on a custom-made polishing apparatus and sequentially polished with Sof-Lex poli-shing disk system including medium disk (with abrasive particle sizes of 10-40 μm), fine disk (with abrasive particle sizes of 3-9 μm) and superfine disk (with abrasive particle sizes of 1-7 μm). Surface roughness (Ra value) and gloss value were measured every 10 seconds until the numerical values were no longer changed. Then the surface roughness, gloss value and polishing time were recorded and the specimen was moved to the next sequence of polishing. Finally, statistical analysis was performed using SPSS 24.0.@*RESULTS@#For all the restorative materials, the Ra values were significantly reduced (P < 0.05) and the gloss values were significantly increased (P < 0.05) after sequentially polishing with Sof-Lex disks. No significant difference was detected among Ra values of all the tested materials (P>0.05) after sequential polishing. The gloss values of LU [(68.1±4.5) GU] and BC [(68.2±5.8) GU] were significantly higher than those of VE [(48.1±8.1) GU] and BC [(53.2±5.8) GU], P < 0.05. To obtain optimal surface smoothness, VM cost the shortest polishing time [40 (30, 55) s] among all the restorative materials (P < 0.05). No significant differences in the total polishing time were observed among VE [140 (135, 145) s], LU [130 (120, 140) s], SB [140 (130, 150) s] and BC [130 (120, 140) s], P>0.05.@*CONCLUSION@#The surface roughness of all CAD/CAM restorative materials were decreased after sequentially polishing with Sof-Lex disk system. To obtain the smoothest surface, different types of restorative materials might need different polishing times using Sof-Lex polishing disk system. For ceramic restorative material VM, we recommend polishing only with medium disk for 40 s. For hybrid restorative material VE and composite restorative material LU, SB and BC, we recommend polishing with medium disk, fine disk and superfine disk in sequence for 130-140 s in total.


Subject(s)
Ceramics , Composite Resins , Computer-Aided Design , Materials Testing , Surface Properties
5.
Braz. dent. j ; 32(6): 54-65, Nov.-Dec. 2021. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1355843

ABSTRACT

Abstract This study aimed to investigate the effect of surface roughness (polished vs. CAD/CAM milling simulation) on impact strength of five dental ceramics for manufacturing CAD/CAM monolithic restorations. Specimens of five ceramics (FC- feldspathic glass-ceramic; PICN- polymer-infiltrated ceramic-network; ZLS- zirconia-reinforced lithium silicate glass-ceramic; LD- lithium disilicate glass-ceramic; YZ- yttria-stabilized tetragonal zirconia polycrystal ceramic) to be tested under impact (15×10×2mm3; n= 15) were divided into two groups, according to surface treatment: polishing (pol) and grinding (gri) as CAD/CAM milling simulation. Impact strength was tested using the Dynstat method. Roughness, topographic, fractographic and finite element analyses were performed. The impact strength data were analyzed by Weibull, and Pearson correlation was used to correlate roughness and impact strength data. The CAD/CAM milling simulation led to significantly (p<0.05) greater roughness (Ra and Rz) and statistically reduced the impact strength for PICN (polPICN= 4.59 to griPICN= 1.09; ±76% decrease), for LD (polLD= 17.69 to griLD= 10.09; ±43% decrease) and for YZ (polYZ= 74.99 to griYZ= 20.67; ±72% decrease) ceramics; and also promoted a more irregular topography with scratches and grooves. Fractographic and FEA analyses depicted the origin of failure at the higher stress concentration side during the impact test, where the pendulum impacted. The CAD/CAM milling simulation significantly decreased the impact strength of the evaluated ceramic materials.


Resumo Este estudo teve como objetivo investigar o efeito da rugosidade da superfície (polido vs. simulação da usinagem em CAD/CAM) na resistência ao impacto de cinco cerâmicas odontológicas indicadas na fabricação de restaurações monolíticas em CAD/CAM. Espécimes de cinco cerâmicas (FC- vitrocerâmica feldspática; PICN- rede de cerâmica infiltrada com polímero; ZLS- vitrocerâmica de silicato de lítio reforçada com zircônia; LD- vitrocerâmica de dissilicato de lítio; YZ- cerâmica policristalina de zircônia tetragonal estabilizada com ítria), a serem testados sob impacto (15 × 10 × 2mm3; n= 15), foram divididos em dois grupos, de acordo com o tratamento superficial: polimento (pol) e desgaste (gri), usado como simulação da usinagem em CAD/CAM. A resistência ao impacto foi testada usando o método Dynstat. Foram realizadas as análises de rugosidade, topografia, fractografia e análise de elementos finitos. Os dados de resistência ao impacto foram analisados pela análise de Weibull, e a correlação de Pearson foi usada para correlacionar os dados de rugosidade e resistência ao impacto. A simulação da usinagem em CAD/CAM levou a uma rugosidade (Ra e Rz) significativamente maior (p < 0,05) para todas as cerâmicas, e reduziu estatisticamente a resistência ao impacto para as cerâmicas PICN (polPICN = 4,59 para griPICN = 1,09; redução de ± 76%), LD (polLD = 17,69 para griLD = 10,09; ± 43% de redução) e YZ (polYZ = 74,99 para griYZ = 20,67; ± 72% de redução); e também promoveu uma topografia mais irregular apresentando riscos e sulcos acentuados. As análises de fractografia e de elementos finitos mostraram a origem da falha no lado de maior concentração de tensão durante o teste de impacto, onde o pêndulo impactou o espécime. A simulação da usinagem em CAD/CAM reduziu significativamente a resistência ao impacto dos materiais cerâmicos avaliados.

6.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 695-700, 2021.
Article in Chinese | WPRIM | ID: wpr-881378

ABSTRACT

Objective@#To explore the key points of clinical diagnosis and treatment of three mesiobuccal root canals.@*Methods@# In the procedure of endodontic therapy for the upper left second molar with pulpitis, through root canal exploration under a dental microscope and cone beam CT (CBCT)-assisted imaging examination, it was confirmed that the left upper second molar contained 3 roots and 5 root canals, among which the third root canal existed in the mesiobuccal root. Combined with perfect root canal preparation, cleaning, disinfection, filling and minimally invasive inlay repair, the clinical symptoms were eliminated. The patients were followed up and the related literatures were reviewed. @* Results @# One- and two-year follow-ups showed that the tooth had no discomfort and could be used normally. X-ray revealed that the filling was complete, and the periapical tissue was normal. The results of the literature review showed that the incidence of three mesiobuccal root canals in maxillary second molars was 0.11%-4.2%. It is difficult to find additional root canals only by X-ray imaging. Dentists should further determine the number and anatomical shape of root canals by CBCT and operating microscopy. When there are three mesiobuccal root canals in maxillary molars, dentists should avoid overpreparation. Healthy tooth tissue is the key to good prognosis. @* Conclusion@#During root canal therapy, clinicians should consider the anatomical variation of the root canal, should always be alert to the existence of an extra root canal, and should use CBCT, operating microscopy, ultrasound and various auxiliary instruments to locate and treat the variant root canal.

7.
West China Journal of Stomatology ; (6): 95-100, 2020.
Article in Chinese | WPRIM | ID: wpr-781338

ABSTRACT

Dental implants have become the main choice for patients to fill in their missing teeth. A precise placement is the basis for a functional and aesthetic restoration. A digital surgical guide is a carrier that transfers the preoperative plan of dental implants to the actual surgery. This paper provides some references that can help clinicians improve the accuracy of implant surgery by stating the development, classification, advantages and disadvantages, and factors that affect the accuracy of digital guides.


Subject(s)
Humans , Computer-Aided Design , Dental Implantation, Endosseous , Dental Implants , Esthetics, Dental , Imaging, Three-Dimensional , Patient Care Planning , Surgery, Computer-Assisted
8.
The Journal of Korean Academy of Prosthodontics ; : 67-76, 2020.
Article in English | WPRIM | ID: wpr-786590

ABSTRACT

With the evolution of the computer-aided design/computer-aided manufacturing (CAD/CAM) technology, the intraoral scanners are playing an increasingly important role, as they are the first step towards a completely digital workflow. The CAD/CAM double scanning technique has been used to transfer the information from provisional restorations to definitive restorations. In this case, a 67-year-old male with esthetically compromised anterior teeth, generalized severe attrition of teeth, and reduced vertical dimension was treated with full mouth rehabilitation including a re-establishment of the lost vertical dimension of occlusion assisted by the crown lengthening procedure. The provisional restorations were fabricated using an intraoral scanner and the CAD/CAM double scanning technique. After the period of adaption, the definitive monolithic zirconia restorations were delivered. The CAD/CAM double scanning technique successfully transferred the occlusal and morphological characteristics, obtained from the provisional restorations, to the definitive restorations.


Subject(s)
Aged , Humans , Male , Crown Lengthening , Dentition , Mouth Rehabilitation , Mouth , Tooth , Tooth Wear , Vertical Dimension
9.
West China Journal of Stomatology ; (6): 263-269, 2020.
Article in Chinese | WPRIM | ID: wpr-827548

ABSTRACT

OBJECTIVE@#To investigate the effects of preparation height and cement space on the fit and retention of computer aided design (CAD)/computer aided manufacturing (CAM) zirconia crown, and to provide reference for the clinical design and fabrication of CAD/CAM crowns.@*METHODS@#3D printing system was used to fabricate resin abutment teeth with convergence angle of 2° and height of 1-3 mm. The models' optical impressions were collected by the three-shape scanner. Then, the cement spaces were set by Cradle CAD/CAM system at 10-50 μm to create an all-ceramic zirconia crown. The fit of the crowns was measured by using silicone rubber interstitial impression method. The retention of the crowns was measured by pull-off test with uniaxial tensile force after the crown was bonded. The data were analyzed by SPSS 22.0 soft-ware.@*RESULTS@#When the preparation height was fixed, the fitness values of different cement space groups have statistical difference (P0.05). The fitness values of different preparation height groups have no statistical difference (P>0.05), and the retention values of different preparation height groups have statistical difference (P0.05).@*CONCLUSIONS@#When cradle CAD/CAM system is used to create a full crown in the clinic, the preparation height should be set to more than 3 mm, and the cement space should be set at 30 μm.


Subject(s)
Computer-Aided Design , Crowns , Dental Porcelain , Dental Prosthesis Design , Zirconium
10.
Journal of Peking University(Health Sciences) ; (6): 762-770, 2020.
Article in Chinese | WPRIM | ID: wpr-942074

ABSTRACT

OBJECTIVE@#To compare the clinical efficacy of a kind of complete dentures fabricated using computer aided design/computer aided manufacturing (CAD/CAM) workflow with that of the complete denture fabricated using conventional workflow.@*METHODS@#Twenty edentulous patients were included in this prospective, single-blind, self-controlled clinical trial. Two pairs of complete dentures were fabricated for each participant: one using the functional suitable denture (FSD) system with CAD/CAM, and the other using conventional fabrication workflow. In the final delivery appointment, the conventional dentures worn by the participant for 3 months at first. Then the participant swapped to wear digital denture for another 3 months. The patients' satisfaction and oral health related quality of life (OHRQoL) were measured using the visual analogue scale (VAS) and oral health impact profile (OHIP-20E) at baseline, 2 weeks, 1 month, 2 months, and 3 months following denture delivery. In addition, the masticatory efficiency of each pair of dentures was measured after three months adaptation period for each type of dentures.@*RESULTS@#The VAS scores of the twenty patients in FSD denture group on general satisfaction, ease of cleaning, ability to speak, esthetics, stability and oral health status on these six domains were higher than that of conventional denture group 3 months after delivery. While the VAS cores in FSD denture group on comfort, ability to chew and ability to chew up were the same as those of conventional denture group. But there was no significant difference (P>0.05). The VAS score on each domain in FSD denture group was higher than that of conventional denture group 3 months after delivery, three domains of which reached statistical significance (P < 0.05), involving functional limitation, psychological discomfort and total. The masticatory performance of the FSD denture (1.20±0.54) was slightly higher than that for the conventional denture (1.16±0.53), but the difference did not reach statistical significance (P=0.691).@*CONCLUSIONS@#The clinical efficacy of the FSD complete denture is comparable to that of the conventional complete denture. As for patient satisfaction and oral health related quality of life, FSD dentures received comparable scores as conventional complete dentures did.


Subject(s)
Humans , Denture, Complete , Patient Satisfaction , Prospective Studies , Quality of Life , Single-Blind Method , Treatment Outcome
11.
West China Journal of Stomatology ; (6): 58-61, 2019.
Article in Chinese | WPRIM | ID: wpr-772699

ABSTRACT

OBJECTIVE@#To study the application of surgical locating guides based on cone beam computed tomography (CBCT) and computer-aided design/computer-aided manufacturing (CAD/CAM) technique on extraction of impacted supernumerary teeth.@*METHODS@#This study included 15 patients with impacted supernumerary teeth in anterior maxillary. Surgical approach was determined by CBCT. Surgical locating guides of labial approach or palatal approach were designed and fabricated by CAD/CAM technique. Impacted supernumerary teeth were extracted under the location of surgical locating guides.@*RESULTS@#Surgical locating guides were well attached in the operation. The impacted supernumerary teeth were located and exposed rapidly, and the adjacent important anatomical structures were avoided.@*CONCLUSIONS@#Surgical locating guides benefit the accurate detection and reduction of trauma in extraction of impacted supernumerary teeth.


Subject(s)
Humans , Cone-Beam Computed Tomography , Maxilla , Tooth Extraction , Tooth, Impacted , Tooth, Supernumerary
12.
The Journal of Korean Academy of Prosthodontics ; : 57-65, 2019.
Article in Korean | WPRIM | ID: wpr-719549

ABSTRACT

Computer aided design and manufacturing and implant surgery using a guide template improve restoration-driven implant treatment procedures. This case utilized those digital technologies to make definitive prostheses for a patient. According to the work flow of digital dentistry, cone beam computed tomography established the treatment plan, which was followed to make the guide template for implant placement. The template guided the implants to be installed as planned. The customized abutments and surveyed fixed restorations were digitally designed and made. The metal framework of the removable partial denture was cast from resin pattern using an additive manufacturing technique, and the artificial resin teeth were replaced with the zirconia onlays for occlusal stability. These full mouth rehabilitation procedures provided functionally and aesthetically satisfactory results for the patient.


Subject(s)
Humans , Computer-Aided Design , Cone-Beam Computed Tomography , Dentistry , Denture, Partial, Removable , Inlays , Mouth Rehabilitation , Mouth , Prostheses and Implants , Tooth , Workflow
13.
The Journal of Korean Academy of Prosthodontics ; : 160-170, 2019.
Article in Korean | WPRIM | ID: wpr-742102

ABSTRACT

The anterior guidance is one of the important factors in prosthodontic treatment of anterior teeth. The lingual surface shape of anterior restorations is so critical that small errors of treatment procedure can cause discomfort of the patient and disharmony of the dentition. If the anterior restorations are achieved harmonious anterior guidance through the fabrication and adjustment of provisional restorations, it is important to accurately reproduce the lingual surface shape of provisional restorations as the final prosthesis. In this case report, it was used the modified Dahl principle and copy-milled technique of computer-aided design/computer-aided manufacturing (CAD/CAM) system for systematic diagnosis and treatment. Therefore, we tried to reconstruct the restoration shape more precisely by setting the appropriate anterior guidance and superimposing the digital image of the abutment teeth and the provisional restorations. Thus, by promoting functional and esthetic recovery, this case report demonstrates satisfying results to both the patients and dentist.


Subject(s)
Humans , Dentists , Dentition , Diagnosis , Prostheses and Implants , Tooth
14.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 198-201, 2019.
Article in Chinese | WPRIM | ID: wpr-751021

ABSTRACT

@#The aims of tooth restoration of endodontically treated teeth are to protect the remaining dental tissue; restore coronal morphology, functions and aesthetics; prevent bacterial microleakage and ensure periodontal healthy; prevent fracture of the restorations and reduce the wear from antagonist teeth. This article reviews the preservation and minimally invasive restoration of endodontically treated teeth. The results of the literature review show that tooth fracture resistance decreases after root canal treatment, the amount of remaining tooth tissue is an important factor affecting the success of root canal treatment, and the neck is the stress concentration area of tooth tissue, the traditional full crown and postcore crown have a certain amount of abrasion on the healthy neck teeth tissue, which will further reduce the bending resistance of the teeth and may cause the teeth to fracture. With the development of bonding technology, composite resin materials and ceramic materials, there are fewer molar tissues removed when resin, inlay, onlay, overlay and inlay crown are used to repair tooth defects, which can better preserve the remaining tooth tissues, especially the neck tooth tissues. After root canal treatment, only the pulp cavity of the tooth can be directly repaired by resin. When the marginal ridge is absent, minimally invasive restoration methods, such as inlay, onlay, and inlay crown, can be selected according to the number of marginal ridges removed and the thickness of the remaining dental tissue.

15.
The Journal of Korean Academy of Prosthodontics ; : 188-198, 2018.
Article in Korean | WPRIM | ID: wpr-715999

ABSTRACT

PURPOSE: Recently, according to the development of digital technology, computer aided design/computer aided manufacture (CAD/CAM) system is widely used for fabrication of various dental prostheses in the field of dentistry. This study aims to survey the present state and awareness of CAD/CAM system on domestic dental field, and to supply the advice for the application of the new system. MATERIALS AND METHODS: In this questionnaire survey was conducted for a total of 298 dentists, dental hygienist and dental technicians of the whole country including the dental hospital of Seoul National University for two months from November to December, 2016 through mail. RESULTS: The most important purpose to consider when purchasing a dental CAD/CAM milling machine were the performance of the milling machine (64.43%) and the use of milling machine was the highest with 49.33% of manufacturing for dental prosthesis and customized implant abutment. In addition, more than 60% of respondents answered positively about the purchase of new milling machine if the CAD/CAM milling machine was improved to satisfactory performance. CONCLUSION: This survey results show that the improved CAD/CAM milling machine would be play an important role in the dental industry in preparation for digitization and the 4th industrial revolution.


Subject(s)
Humans , Dental Hygienists , Dental Prosthesis , Dental Technicians , Dentistry , Dentists , Postal Service , Seoul , Surveys and Questionnaires
16.
The Journal of Advanced Prosthodontics ; : 335-339, 2018.
Article in English | WPRIM | ID: wpr-742060

ABSTRACT

PURPOSE: The purpose of the present study was to compare scanning trueness and precision between an abutment impression and a stone model according to dental computer-aided design/computer-aided manufacturing (CAD/CAM) evaluation standards. MATERIALS AND METHODS: To evaluate trueness, the abutment impression and stone model were scanned to obtain the first 3-dimensional (3-D) stereolithography (STL) file. Next, the abutment impression or stone model was removed from the scanner and re-fixed on the table; scanning was then repeated so that 11 files were obtained for each scan type. To evaluate precision, the abutment impression or stone model was scanned to obtain the first 3-D STL file. Without moving it, scanning was performed 10 more times, so that 11 files were obtained for each scan type. By superimposing the first scanned STL file onto the other STL files one by one, 10 color-difference maps and reports were obtained; i.e., 10 experimental scans per type. The independent t-test was used to compare root mean square (RMS) data between the groups (α=.05). RESULTS: The RMS±SD values of scanning trueness of the abutment impression and stone model were 22.4±4.4 and 17.4±3.5 µm, respectively (P < .012). The RMS±SD values of scanning precision of the abutment impression and stone model were 16.4±2.9 and 14.6±1.6 µm, respectively (P=.108). CONCLUSION: There was a significant difference in scanning trueness between the abutment impression and stone model, as evaluated according to dental CAD/CAM standards. However, all scans showed high trueness and precision.

17.
Journal of Dental Rehabilitation and Applied Science ; : 196-207, 2018.
Article in Korean | WPRIM | ID: wpr-739880

ABSTRACT

An accurate implant placement with ideal location is significant for long-term success of the implant. An exact evaluation of nearby anatomic structures such as quality of residual bone, an inferior alveolar bone and a maxillary sinus is required. For a prosthetic-driven treatment, planned surgery, precise prosthesis and communication with the patient are significant requisites especially for full-mouth rehabilitation. In this case, the patient with severe alveolar bone resorption had a CT guided surgery supported by CT data and the data from scanning diagnostic wax-up. Afterward, edentulous area was restored by full mouth implant-supported prosthesis by using monolithic zirconia and CAD/CAM technique. This paper reports the outcome of the procedure which was remarkable both esthetically and functionally.


Subject(s)
Humans , Bone Resorption , Maxillary Sinus , Mouth Rehabilitation , Mouth , Prostheses and Implants , Rehabilitation
18.
Maxillofacial Plastic and Reconstructive Surgery ; : 2-2018.
Article in English | WPRIM | ID: wpr-741578

ABSTRACT

With the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology, it has been possible to reconstruct the cranio-maxillofacial defect with more accurate preoperative planning, precise patient-specific implants (PSIs), and shorter operation times. The manufacturing processes include subtractive manufacturing and additive manufacturing and should be selected in consideration of the material type, available technology, post-processing, accuracy, lead time, properties, and surface quality. Materials such as titanium, polyethylene, polyetheretherketone (PEEK), hydroxyapatite (HA), poly-DL-lactic acid (PDLLA), polylactide-co-glycolide acid (PLGA), and calcium phosphate are used. Design methods for the reconstruction of cranio-maxillofacial defects include the use of a pre-operative model printed with pre-operative data, printing a cutting guide or template after virtual surgery, a model after virtual surgery printed with reconstructed data using a mirror image, and manufacturing PSIs by directly obtaining PSI data after reconstruction using a mirror image. By selecting the appropriate design method, manufacturing process, and implant material according to the case, it is possible to obtain a more accurate surgical procedure, reduced operation time, the prevention of various complications that can occur using the traditional method, and predictive results compared to the traditional method.


Subject(s)
Calcium , Durapatite , Imaging, Three-Dimensional , Methods , Polyethylene , Plastic Surgery Procedures , Titanium
19.
The Journal of Korean Academy of Prosthodontics ; : 126-133, 2018.
Article in Korean | WPRIM | ID: wpr-714249

ABSTRACT

The development of cone beam computerized tomography (CBCT) allows three-dimensional analysis of the patient's anatomy. The surgical guide is a combination of CBCT, computer-aided design/computer-aided manufacturing (CAD/CAM) and implant diagnostics software, which allows well planned prostheses design and ideal implant placement. Guided surgery minimizes possible anatomical damage and allows for more reproducible treatment planning. In this case, the operation time was shortened by using a surgical guide for multiple implants placement in a fully edentulous patient. Immediate loading were performed more easily using preliminary preparation of provisional prosthesis. The patient was satisfied with improved esthetics and chewing function.


Subject(s)
Humans , Cone-Beam Computed Tomography , Esthetics , Mastication , Mouth Rehabilitation , Mouth , Prostheses and Implants
20.
The Journal of Korean Academy of Prosthodontics ; : 166-172, 2018.
Article in Korean | WPRIM | ID: wpr-713964

ABSTRACT

In case of the treatment of maxillary anterior teeth, it should be taken into account the proper morphology, arrangement and color satisfying patient's esthetic demands. For this purpose, facial composition, dentofacial composition, dental composition and dentogingival composition should be considered making diagnosis and treatment plan in an esthetic point of view. In adjustable temporary crown state, careful evaluation and correction of the esthetic and functional aspect were performed, and the definite restoration was reproduced using double scan.


Subject(s)
Humans , Crowns , Diagnosis , Tooth
SELECTION OF CITATIONS
SEARCH DETAIL